1.1
What is the required weighing capacity?
The required weighing capacity of the weigh module is not only determined by the heaviest product weight.
Other factors, such as additional installations or customized weighing pans, have to be added. Therefore, use the following formula:
C ≥ Wmax + WP + WC + WAPL
Compact high-precision weigh modules without display are designed for integration into machines.
Therefore, parameter "WP" is zero, because the weighing pan is part of standard delivery and weight is factory adjusted.
Enter your values:
Weight of additional permanent
installation on top of weighing pan?
g
Maximum weight of your
product?
Pre Load:
g
Weight of Container to
weigh products?
g
Tare weight:
Maximum weight:
You need a weigh module with a capacity of least:
g